Exinda 12 Ton Commercial Air-to-Water Heat Pump Chiller
Key specifications
Product description
The Exinda 12 ton commercial heat pump chiller is an air-to-water unit delivering approximately 42 kW of heating and cooling capacity for hotels, offices, restaurants, clinics and light industrial buildings. The unit replaces separate boiler and chiller systems with a single piece of equipment providing heating, cooling and domestic hot water production. It integrates with standard hydronic distribution: fan-coil units, air handling units (AHUs), underfloor heating systems and process loops. Inverter scroll compressor technology maintains high efficiency at part-load conditions, which dominate real-world operating hours in commercial buildings. The unit is designed for continuous duty with serviceable components accessible from the front and sides. European voltage adaptation is available on request. CENTRO-GAS, a Novi Sad industrial heating company with an in-house installation and service team, provides system specification, installation, commissioning and maintenance contracts. EXINDA backs the unit with factory-level technical support and an EU service and engineering center in Italy.
More about this unit
How does it integrate with hydronic distribution systems?
What is the business case for a commercial heat pump chiller?
European voltage adaptation and project-specific configuration
Why CENTRO-GAS as the commercial heat pump partner?
Technical specifications
| Heating | |
|---|---|
| Nominal heating capacity | 45 kW |
| COP at rated conditions | 3.86 - 4.49 |
| SCOP (seasonal) | 4.74 |
| Energy class, heating | A+++ |
| Maximum flow temperature, heating | 60 °C |
| Cooling | |
| Nominal cooling capacity | 34 kW |
| EER at rated conditions | 2.74 - 3.25 |
| SEER (seasonal) | 4.56 |
| Energy class, cooling | A++ |
| Chilled water temperature range | 7 - 27 °C |
| Domestic hot water | |
| Max. DHW temperature | 60 °C |
| DHW recovery method | External plate HX or storage tank |
| Refrigerant | |
| Refrigerant type | R290 (Propane) |
| Refrigerant charge | 3.5 kg |
| GWP | 3 |
| Electrical | |
| Power supply | 380 - 400 V / 3ph / 50 Hz |
| Nominal power input | 3.32 - 10.53 kW |
| Max. input current (per phase) | 40 A (MCA) |
| Recommended circuit breaker | 50 A (MOP) |
| European voltage adaptation | Available on request |
| Compressor | |
| Compressor type | DC inverter EVI scroll |
| Number of compressors | 1 |
| Capacity modulation range | 30 - 100 % |
| Operating range | |
| Outdoor temperature, heating | -25 - 43 °C |
| Outdoor temperature, cooling | -15 - 43 °C |
| Dimensions and weight | |
| Unit dimensions (H x W x D) | 2118 x 1135 x 1035 mm |
| Operating weight | 400 kg |
| Hydraulic connections | 2 inch female thread |
| Noise | |
| Sound power level Lw(A) | 65 dB(A) |
| Sound pressure level at 1 m | 61 dB(A) |
| Night / reduced-noise mode | Standard (58 dB(A)) |
| Controls and communication | |
| Onboard controller | Intelligent Microcomputer |
| BMS protocols | Modbus |
| Remote monitoring | Optional WiFi / 4G |
| Service access | |
| Panel access | Front and side serviceable |
| Compressor replacement | Field-serviceable |
| Identifiers and compliance | |
| Model code | FBMBHT4B2E3 |
| Warranty, unit | 10 |
| Warranty, compressor | 10 |
| Certifications | CE, ErP |
Documentation
System integration and installation requirements
System architecture overview
The 12-ton chiller connects to the building's hydronic network via flow and return piping. A buffer tank or thermal store is recommended for systems with highly variable loads (hotels, mixed-use buildings) to prevent short-cycling. The unit's onboard controller manages compressor staging, defrost logic and flow temperature setpoints. Integration with a building management system (BMS) via Modbus allows centralised monitoring of operating parameters, fault alerts and energy metering. For buildings requiring simultaneous heating and cooling (common in hotel complexes), a four-pipe hydronic design or heat recovery configuration should be specified at the design stage.
Site requirements
- Plant room or outdoor installation area: clearance for airflow, service access and noise compliance. Weight loading for rooftop installations must be verified.
- Electrical supply: 380 V three-phase, dedicated circuit, breaker 50 A (MOP). Voltage adaptation for non-standard local supply available on request from EXINDA.
- Hydraulic connections: 2 inch flow and return, insulated, with vibration isolators at the unit.
- Condensate management: commercial-grade drainage with freeze protection.
- BMS connectivity: Modbus cabling to the building's control system (if applicable).
Compatible distribution systems
| Distrubution type | Typical supply temperature | Application |
|---|---|---|
| Fan-coil units (2-pipe) | 7-12 °C cooling / 40-55 °C heating | Offices, hotels, retail |
| Fan-coil units (4-pipe) | Simultaneous heating and cooling | Hotels, mixed-use |
| Air handling units (AHU) | 7-12 °C cooling / 40-55 °C heating | Large open-plan offices, retail |
| Underfloor heating | 30-40 °C | Ground-floor retail, lobbies |
| DHW production | 50-65 °C via plate HX or tank | Hotels, restaurants, clinics |
| Process loops | Application-dependent | Light industry, food service |
What is NOT included in delivery
- Buffer tank / thermal store
- Hydraulic distribution manifold and pump groups
- Fan-coil units, AHUs or other terminal equipment
- BMS integration wiring and programming
- Structural supports for rooftop installation
- Electrical wiring from the distribution board to the unit
- Installation and commissioning labour (quoted as part of the CENTRO-GAS project proposal)
Other capacity options
Operating economics, compliance and procurement
Operating cost and ROI logic
Heat pumps deliver roughly 3 to 4 times more thermal energy than the electricity they consume, which translates to significantly lower energy costs compared to gas or oil boiler systems at current Serbian tariffs. For a commercial building, the calculation is project-specific: it depends on current energy consumption, tariff structure, operating hours, part-load profile and the cost of the existing plant. CENTRO-GAS prepares a project-specific ROI analysis using the building's actual consumption data. Generic payback claims are not offered because they do not account for real operating conditions.
Request a project-specific ROI analysis >ESG and tender compliance
Zero on-site combustion eliminates CO, NOx and particulate emissions from the building's heating system. Low-GWP refrigerant options, high seasonal efficiency and EU-standard certifications (CE, ErP) support ESG reporting, green building certification (LEED, BREEAM or national equivalents) and eligibility for public tenders that require energy-efficiency documentation. CENTRO-GAS provides the compliance documentation needed for these processes.
Ask about compliance documentation >Commercial procurement and lead times
The 12-ton chiller is available through CENTRO-GAS as a project-based quotation covering the unit, installation, commissioning and maintenance contract. Lead times depend on configuration (standard or European voltage-adapted). For resellers, volume terms and stocking arrangements are discussed directly with the CENTRO-GAS commercial team. EXINDA's factory capacity of 90,000 units per year and established container logistics to Serbia provide supply reliability.
Contact the commercial team >Frequently asked questions about this unit
What building size does a 12-ton chiller cover?
A 12-ton (approximately 42 kW) unit covers light commercial buildings with heating and cooling loads in the 30 to 50 kW range. Typical examples include small to mid-sized hotels (30 to 60 rooms), office buildings of 500 to 1,500 m², restaurants, clinics and light industrial facilities. The correct sizing depends on a load calculation based on the building's characteristics, which CENTRO-GAS provides as part of the project proposal. For larger buildings, the 24-ton unit or multiple units in cascade are available.
Can it replace an existing gas boiler system?
Yes. The unit connects to existing hydronic distribution (radiators, fan-coils, underfloor). A retrofit assessment determines whether the existing piping, pump groups and terminal equipment are compatible with the heat pump's flow temperature range. EXINDA's Milano commercial boiler-room retrofit is a direct precedent (attributed to EXINDA). CENTRO-GAS has industrial heating expertise on both the boiler and the heat pump side, which is critical for hybrid and phased retrofit designs.
Does it provide both heating and cooling?
Yes. The unit operates as a heat pump in winter (producing hot water) and as a chiller in summer (producing chilled water), using the same hydronic distribution. This replaces two separate pieces of equipment with one, reducing capital cost, plant-room footprint and maintenance overhead.
What refrigerant does it use?
The unit uses R290 (Propane) refrigerant, which has a very low Global Warming Potential (GWP) of 3. Confirm the specific charge with CENTRO-GAS when requesting a quotation.
Is European voltage adaptation standard or an additional cost?
European voltage adaptation is available on request and is coordinated through EXINDA's EU service and engineering center in Italy. Confirm lead time and any cost differential with CENTRO-GAS when specifying the project.
What are the lead times?
Lead times depend on whether the unit is a standard configuration or requires European voltage adaptation or other project-specific modifications. CENTRO-GAS confirms availability and delivery timeline at the quotation stage. EXINDA's factory capacity of 90,000 units per year supports reliable supply.
Does it work at -20 °C outdoor temperature?
EXINDA tests its commercial range in climate chambers down to -35 °C. The unit is certified for operation at outdoor temperatures as low as -25 °C. EXINDA's large cascade installations in northern China have operated stably at -25 °C to -40 °C since 2010 (attributed to EXINDA). For extreme cold or critical applications, a hybrid configuration with a backup boiler is a proven approach.
How does it connect to the building management system (BMS)?
The unit supports Modbus communication protocol. BACnet availability should be confirmed for the specific model configuration. Integration allows centralised monitoring of operating status, fault codes, energy consumption and temperature setpoints. CENTRO-GAS can coordinate BMS integration as part of the project scope.
What service and maintenance is required?
Commercial heat pump chillers require periodic inspection: compressor health checks, refrigerant pressure and charge verification, heat exchanger cleaning, electrical connection inspection and control system updates. CENTRO-GAS offers maintenance contracts with defined service levels, including response-time commitments. The unit is designed with front and side service access for field-serviceable compressor and component replacement.
Can resellers stock and sell this unit?
Yes. CENTRO-GAS holds exclusive EXINDA distribution for Serbia and supplies resellers under commercial terms. The partnership includes product training, installation and service education, and terms that scale with volume. Commercial projects represent higher-value, occasional opportunities for resellers who primarily serve the residential market. Contact the CENTRO-GAS commercial team for reseller terms.